-- Title: Nishan SNTP Configuration MIB
-- Description:
-- This MIB contains management objects for Nishan SNTP configuration.
-- This MIB is supported on IPS Series 3000, 4000 and 5000 switches.
-- Version 1.0
--
-- Revision history:
--
-- 05/06/03: initial version released.
-- 05/08/03: Incorporate review comments.NISHAN-SNTP DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPEFROM SNMPv2-SMI
InetAddress,InetAddressTypeFROM INET-ADDRESS-MIB
nishan
FROM NISHAN-SMI;idbNishanSNTP MODULE-IDENTITYLAST-UPDATED"0305060000Z"ORGANIZATION"Nishan Systems, Inc"CONTACT-INFO"Nishan Systems, Inc
Attn: Network Management
3850 North First Street
San Jose, CA 95134
USA
Tel : +1 408 519-3700
email : snmp@nishansystems.com"DESCRIPTION"The private MIB for Nishan SNTP configuration"REVISION"0305060000Z"DESCRIPTION"Initial public release of this MIB module"::={ nishan 23}-- =======================================================================
-- SNTP Configuration
-- =======================================================================sntpAdminStatus OBJECT-TYPESYNTAXINTEGER{enable(1), disable(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"{disable}
This field is used to enable/disable the admin status of SNTP protocol."::={ idbNishanSNTP 1}sntpRole OBJECT-TYPESYNTAXINTEGER{ client(1), server(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"{ client }
Specifies whether the SNTP protocol is configured as a client SNTP or as a
server SNTP. Client SNTP will synchronize it's clock to that of a Server.
User must first disable SNTP (by setting the Admin status to disable) before
changing SNTP roles."::={idbNishanSNTP 2}sntpServerIpAddressType OBJECT-TYPESYNTAXInetAddressTypeMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The type of Inet address in sntpServerIpAddress."::={ idbNishanSNTP 3}sntpServerIpAddress OBJECT-TYPESYNTAXInetAddressMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"{ 0 }
The IP address of the SNTP Server. When the switch is configured as a SNTP server,
This value has no meaning."::={ idbNishanSNTP 4}sntpTimeZone OBJECT-TYPESYNTAXINTEGER(-720..840)MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"{ 0 }
Specifies the timezone where the switch resides in.
The timezone is represented in minutes with respect to GMT (0)."::={ idbNishanSNTP 5}
sntpDaylightSavingsTime OBJECT-TYPESYNTAXINTEGER{enable(1), disable(2)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"{ disable }
Specifies whether the Daylight Savings time is observed or not. Value of disable(1) specifies that
daylight savings time is not observed."::={ idbNishanSNTP 6}sntpClientState OBJECT-TYPESYNTAXINTEGER{ operational(1), error(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"{ operational }
Specifies the operational state of the Client SNTP. Value of Error indicates that client
encountered an operational error, such as not being able to contact Server."::={ idbNishanSNTP 7}END